Error message

Deprecated function: The each() function is deprecated. This message will be suppressed on further calls in menu_set_active_trail() (line 2404 of /home/mme/murty/includes/menu.inc).

Facilities

Research Facilities of Prof. B.S. Murty’s Group

Nanotech Lab In-charge: T. Gopi, +91-9603109241, gopitalluri549 @ gmail.com

Note: In case of paying the usage charges through Project funds then Kindly fill the fund transfer form and submit it to the equipment in-charge along with the Job requisition form.

Equipment List in MSB 202

S.No

Equipment Name

Location

Major specs

Student in-charge

  1.  

XRD (X'pert Pro PANalytical)
XRD requisition form

Nanotech lab

High temperature XRD (up to 1500 ̊C), Small angle XRD

1. Priyesh: priyeshpmt @ gmail.com, 2. Soumya: somranjan21 @ gmail.com, 3. Gourav: gourav.nitdurgapur.mse17 @ gmail.com

  1.  

Surface Area Analyser (SMART SORB 92)
BET requisition form

NAC 218

Pore volume, surfaced area, True Volume

1. Lava Kumar: lavakumar.rgukt @ gmail.com, 2. Sri Pooja: sripooja.mishra @ gmail.com, 3. Nischay: gnkaushik92 @ gmail.com

  1.  

Particle Size Analyser (Microtrac)
PSA requisition form

NAC 218

Nano particle analysis

1. Sri Pooja: sripooja.mishra @ gmail.com, 2. Nischay: gnkaushik92 @ gmail.com

  1.  

DSC (SETARAM Labsys 1600 °C)
High Temperature DSC requisition form

NAC 218

Temperature capability up to 1600 ̊C

1. Adil: adilmmt01 @ gmail.com, 2. Anil Bandi: , 3. Sufyan: sufyanshk @ gmail.com

  1.  

Dilatometer (SETARAM SETSYS Evolution)
Dilatometer requisition form

NAC 218

-

1. Karthick G: karthickg2013 @ gmail.com, 2. Revathi G: revati.g191 @ gmail.com

  1.  

DSC (Perkin Elmer Diamond DSC 600 °C)
Low Temperature DSC requisition form

NAC 218

Temperature capability up to 600 ̊C

1. Anil Bandi: , 2. Sufyan: sufyanshk @ gmail.com

 

7.

Fritsch P-5 High Energy Planetary Ball Mills - 3
Ball Mill requisition form

NAC 218

Wet and dry milling at room temperature (atmospheric condition)

1. Rahul Bhattacharya: rahulbnitrr @ gmail.com, 2. Nischay: gnkaushik92 @ gmail.com

 

8.

Glove Box

NAC 218

-

1. Priyesh: priyeshpmt @ gmail.com, 2. Karthick G: karthickg2013 @ gmail.com

 

9.

Compaction unit (Insmart Systems)

NAC 218

20 ton

1. Adil: adilmmt01 @ gmail.com, 2. Soumya: somranjan21 @ gmail.com, 3. Gourav: gourav.nitdurgapur.mse17 @ gmail.com

10.

Vacuum Arc Melting Unit (VEC Solutions)

NAC 218

Suction casting (rod and Tube) Pressure=10-6m bar

1. Adil: adilmmt01 @ gmail.com, 2. Gopi: gopitalluri549 @ gmail.com, 3. Hariharan: rajhharan97 @ gmail.com

11.

High Vacuum Furnace (SWAMEQIP 1400 °C)

NAC 218

Operating at 900 ̊C, Pressure=10-6 m bar

1. Rahul John: rahuljohn77 @ gmail.com, 2. Gourav: gourav.nitdurgapur.mse17 @ gmail.com, 3. Anil:

Equipment List outside MSB 202

 

Equipment Name

Location

Major specs

Student in-charge

  1.  

Zoz Simoloyer CM 01
Simoloyer Job requisition form

Metal Forming lab

Dry milling at room temperature (atmospheric condition)

1. Karthick G: karthickg2013 @ gmail.com, 2. Nischay: gnkaushik92 @ gmail.com, 3. Sivaji:

  1.  

Spark Plasma Sintering Furnace

Metal Forming lab

Temperature capability up to 2000 ̊C, Pressure = 100 MPa

1. Rahul John: rahuljohn77 @ gmail.com, 2. Sufyan: sufyanshk @ gmail.com

  1.  

Carbolite High Temp. Furnace

Materials Processing lab

Temperature of operation=1600oC

1. Tripta: tripta.parida @ gmail.com, 2. Revathi: revati.g191 @ gmail.com

  1.  

Resistance Heating furnace (INDFURR 1400 °C)

Physical Metallurgy Lab

Ar gas purging facility, Operating at 1300 ̊C

1. Tripta: tripta.parida @ gmail.com, 2. Revathi: revati.g191 @ gmail.com

  1.  
Nano Indenter (Hysitron)

AFM Lab

Nano hardness, reduced Young’s modulus

1. Revathi: revati.g191 @ gmail.com, 2. Priyesh: priyeshpmt @ gmail.com